Approved Testing Scope |
Electrical apparatus for Explosive gas and dust atmospheres |
General requirements - construction, safety and Marking |
IEC60079-0:2011 |
|
../Thermal endurance to heat |
IEC60079-0 / Clause 26.8 |
A |
../Thermal endurance to cold |
IEC60079-0 / Clause 26.9 |
A |
../Resistance to impact |
IEC60079-0 / Clause 26.4.2 |
A |
../Temperature test |
IEC60079-0 / Clause 26.5.1 |
A |
../Thermal shock test |
IEC60079-0 / Clause 26.5.2 |
A |
../Torque test for bushing |
IEC60079-0 / Clause 26.6 |
A |
../Resistance to chemical agents for Group I |
IEC60079-0 / Clause 26.11 |
A |
../Earth continuity |
IEC60079-0 / Clause 26.12 |
A |
../Surface resistance test of parts of enclosures of non-metallic materials |
IEC60079-0 / Clause 26.13 |
A |
../Measurement of capacitance |
IEC60079-0 / Clause 26.14 |
A |
Electrical apparatus for Explosive gas and dust atmospheres |
Increased safety 'e' |
IEC60079-7:2015 |
|
.../ all |
.../Dielectric strength |
IEC60079-7 / Clause 6.2 |
A |
.../Cells and batteries |
.../Insulation resistance |
IEC60079-7 / Clause 6.7.1 |
A |
.../ connection and junction boxes |
.../General requirements |
IEC60079-7 / Clause 6.9.1 |
A |
.../max. dissipated power method |
IEC60079-7 / Clause 6.9.2 |
A |
.../Defined arrangement method |
IEC60079-7 / Clause 6.9.3 |
A |
.../ resistance heating devices and resistance heating units other than trace heating |
.../insulation integrity test |
IEC60079-7 / Clause 6.10.2 |
A |
.../thermal stability of the insulation materials |
IEC60079-7 / Clause 6.10.3 |
A |
.../Resistance to impact |
IEC60079-7 / Clause 6.10.4 |
A |
.../Cold start current |
IEC60079-7 / Clause 6.10.5 |
A |
.../test for specific forms of resistance devices and units |
IEC60079-7 / Clause 6.10.6 |
A |
Electrical apparatus for Explosive gas and dust atmospheres .../ trace heating |
Electrical trace heating |
IEC60079-30-1 : 2007 |
|
All testing |
|
A |
|
|
|